All 18 codes
A dot is part of how the display shows some codes: E2.1 and E21 are the same code.
| Code | Manufacturer's meaning | In plain language | Applies to |
|---|---|---|---|
| E01 | Loss of the IRQ or other internal failures (Internal IFC error) | The furnace control board has reported an internal error of its own. | All 33 models |
| E04 | Open Limit (Main Thermal, Rollout Switch, or Reverse Airflow Switch) | A temperature safety switch in the furnace has opened. The manual describes these as safety devices that open when an abnormally high temperature is sensed. More on E04 | All 33 models |
| E05 | Flame detected, should not be present | The furnace senses a flame at a time when there should be none. | All 33 models |
| E08 | Flame current is low, but still strong enough to allow operation | The furnace is still able to run, but its flame-sensing signal is weaker than it should be. | All 33 models |
| E09 | Open Inducer Limit Switch or Condensate Pressure Switch | A safety switch on the venting or condensate-drain side of the furnace has opened. | All 33 models |
| E11 | (1) 1st stage gas valve not energized when it should be (2) 1st stage gas valve relay stuck closed (3) 2nd stage gas valve relay stuck closed (Not applicable for S9X1/S9B1) (4) 2nd stage gas valve energized when it should not be (Not applicable for S9X1/S9B1) (5) 2nd stage gas valve not energized when it should be (Not applicable for S9X1/S9B1) | The control has detected a fault in the gas valve circuit or its relays. | All 33 models |
| E12 | Open fuse | The fuse on the furnace control board is open or missing. | All 33 models |
| E2.1 | Retry Exceeded (Flame never sensed, one hour lockout after 3 times) | The furnace tried to light and did not sense a flame, so it has locked itself out for one hour. More on E2.1 | All 33 models |
| E2.2 | Recycles Exceeded (Flame sensed then lost, one hour lockout after 10 times) | The furnace had to restart its heating cycle repeatedly and has locked itself out for one hour. The manual describes this as the flame being sensed and then lost; the wiring-diagram legend also lists the pressure switch opening ten times. | All 33 models |
| E2.3 | 1st Stage Gas Valve Not Energized When It Should Be exceeded after 10 times | The control did not see the gas valve switch on when it should have, ten times in a row. | All 33 models |
| E3.1 | Shorted Pressure Switch, 1st Stage | The furnace sees its draft pressure switch closed when it should be open. | All 33 models |
| E3.2 | Open Pressure Switch, 1st Stage | The furnace sees its draft pressure switch open when it should be closed. More on E3.2 | All 33 models |
| E3.3 | Shorted Pressure Switch, 2nd Stage (Not applicable for S9X1/S9B1) | The furnace sees its second-stage draft pressure switch closed when it should be open. | S9X2 models only |
| E3.4 | Open Pressure Switch, 2nd Stage (Not applicable for S9X1/S9B1) | The furnace sees its second-stage draft pressure switch open when it should be closed. | S9X2 models only |
| E6.1 | Voltage reversed polarity | The furnace reports that its incoming power wiring polarity is reversed. | All 33 models |
| E6.2 | Bad grounding | The furnace reports that it does not sense a proper electrical ground. | All 33 models |
| E6.3 | (1) Igniter relay fails (2) Igniter open | The furnace reports a problem with its igniter or the relay that powers it. | All 33 models |
| E7.1 | 1st Gas valve (MVL) is energized when it should be off | The control senses power at the gas valve when the valve should be off. | All 33 models |
What to do with a code
For these furnaces, the manufacturer's troubleshooting for every code on this list is technician work: it involves gas, flame, venting, wiring or the control board. A code is still useful to you, because it shortens the call.
- Write the code down exactly as shown, and whether it stays or comes and goes.
- Have the model number ready from the furnace rating label.
- Note what the furnace was doing: trying to start, running, or not responding.
If the code cannot be read without opening a furnace panel, do not remove the panel just to find it. The diagnostic helper works from symptoms and does not need a code.
If you smell gas, a carbon monoxide alarm sounds, or you see smoke or fire, leave the house and call your gas utility or 911 from outside.
Where the code is shown
On the small digital display of the furnace's integrated furnace control, the control board inside the furnace. It is not a thermostat code and it does not appear on the outdoor unit. The control stores the last six faults, so a technician can read the history even after the display has gone back to idle (IdL).
Which furnaces this covers
The 33 model numbers printed in the manual: 11 each in the S9X1, S9X2 and S9B1 series. Codes E3.3 and E3.4 apply to the 11 S9X2 models only; the manual marks them "Not applicable for S9X1/S9B1".
Show the 33 model numbers
- S9B1B040D3PSAB
- S9B1B040U3PSAB
- S9B1B060D3PSAB
- S9B1B060U4PSAB
- S9B1B080D4PSAB
- S9B1B080U4PSAB
- S9B1C080U5PSAB
- S9B1C100D5PSAB
- S9B1C100U5PSAB
- S9B1D120D5PSAB
- S9B1D120U5PSAB
- S9X1B040D3PSBB
- S9X1B040U3PSBB
- S9X1B060D3PSBB
- S9X1B060U4PSBB
- S9X1B080D4PSBB
- S9X1B080U4PSBB
- S9X1C080U5PSBB
- S9X1C100D5PSBB
- S9X1C100U5PSBB
- S9X1D120D5PSBB
- S9X1D120U5PSBB
- S9X2B040D3PSBB
- S9X2B040U3PSBB
- S9X2B060D3PSBB
- S9X2B060U4PSBB
- S9X2B080D4PSBB
- S9X2B080U4PSBB
- S9X2C080U5PSBB
- S9X2C100D5PSBB
- S9X2C100U5PSBB
- S9X2D120D5PSBB
- S9X2D120U5PSBB
Source
Trane installation manual FNR-SVX002C-EN (November 2026), Tables 42 and 43 (pages 97-98). Checked on . The manual supplied with your furnace is the authority for your unit.
HomeFixHelpHQ drafted this page with AI assistance from the manufacturer's installation manual. The code meaning is the manufacturer's; the plain-language explanation is ours. No licensed HVAC technician has reviewed it and nobody inspected a furnace for it. This is general information, not a diagnosis of your furnace. Safety & Content Disclaimer.